The framework

One framework for automated BIM design.

Every Orange Button product runs on the same framework. It reads your BIM model, finds where a solution is needed, checks the conditions, selects what the rules allow and places it in the model. Firestop is the first discipline: the rules of tested firestop systems, applied to every penetration.

Your BIM modelIFC or Revit: walls and floors with their fire rating, and every service.
Tested systemsThe Field of Application of manufacturers on the platform.Manufacturer databaseLive API link →
Orange Button framework
  1. Data checkIs the information a solution needs in the model?Firestop: fire ratings, installation types, dimensions, insulation types and thicknesses
  2. IdentificationEvery place in the model that needs a solution.Firestop: every penetration through a fire-rated wall or floor
  3. EngineeringThe conditions checked against the requirements.Firestop: opening, supports, A, B and C distances
  4. SelectionThe solution the rules allow.Firestop: the tested system from the Field of Application
  5. PlacementThe solution as an object in the model, with its data.Firestop: the seal, ready to quote and install
OB BIM →Compliant designEvery penetration matched to a tested system.OB Office →QuoteQuantities and costs per penetration.OB Field →On siteInstalled as designed, with proof.

OB Field → Your BIM modelStatus, photos and registrations from site flow back into the project, as proof and as-built record.

Same model, same rules, same result: every choice traceable to a tested system.

What goes in

Two sources, one design.

  • 01

    Your BIM model

    Architectural, structural and MEP models as IFC (Open BIM) or straight from Autodesk Revit. Walls, floors, fire ratings and every pipe, duct and cable tray.

  • 02

    Tested firestop systems

    The Field of Application of manufacturers on the platform: which solution may be used where, for which construction, service and fire rating. Manufacturers can link their own Field of Application database with an API, so every change comes through automatically. You choose your preferred manufacturers.

What it knows

The rules of the certificate, applied to every penetration.

A seal is only certified when the whole system matches the test. The framework checks every condition, for every penetration, every time.

  • Wall and floor build-up

    Construction type, thickness and fire rating of the barrier.

  • Opening size and shape

    Round or rectangular, and within the tested dimensions.

  • Supports

    Services supported at the tested distance from the fire barrier.

  • Multi-service layout

    Which element types may share one opening, and the maximum MSP size.

  • A, B and C distances

    Between installations, to the edge of the opening and inside one MSP.

  • Service and insulation

    Combustible or non-combustible pipes, cables and insulation, each with their own solutions.

How it works

Five steps, at the push of a button.

  1. 01

    Data check

    Before anything else, the framework checks whether the model holds the information a solution needs. Missing data is flagged, so the design rests on reliable input.

    Firestop: missing fire ratings, installation types, dimensions, insulation types and thicknesses.

    OB BIM
  2. 02

    Identification

    The framework finds every place in the model where a solution is needed, and gives each one a unique, numbered position, ready for quotation.

    Firestop: every service through a fire-rated wall, floor or builders work opening: one position, one clash.

    OB BIM
  3. 03

    Engineering

    Engineering checks the conditions around each position against the requirements of the solutions, and flags every deviation before the design is made.

    Firestop: the Compliance Checker measures distances within and between openings, multi-service layouts and supports.

    OB BIM
  4. 04

    Selection

    Each position is matched to the solutions the rules allow, from your preferred suppliers, with the reason why others don’t fit.

    Firestop: only firestop systems whose Field of Application fits are proposed.

    OB Office
  5. 05

    Placement

    The chosen solution goes back into the model as a BIM object, with quantities and costs. The same design goes to site, where the installation is registered.

    Firestop: the tested seal in the model, and every seal registered on site as installed.

    OB Office · OB Field

Principles

Why a framework, not just a tool.

One framework, every discipline
Firestop is the first. The same five steps work for any trade whose solutions follow rules, so new disciplines build on what is already there.
Rule-based and repeatable
The same model and the same rules give the same design, whoever runs it.
Tested systems only
No engineering judgements, no grey area: only what the certificate allows.
Open BIM
IFC in, BIM objects out. Works with the models your partners already make.
Secure by design
ISO 9001 quality management and ISO 27001 information security.

Put the framework to work on your next project.

Start free with 200 clashes a month, or book a demo with your own BIM model.